AC Gas Refill — Leak Test First, Then Refill in Mohammadpur, Dhaka

5.0
0 Reviews
AC Gas Refill — Leak Test First, Then Refill

Overview of AC Gas Refill — Leak Test First, Then Refill in Mohammadpur

Your AC is running but the room is not getting cold? The most common reason is low refrigerant gas. But before we refill anything, we make sure the gas will actually stay — because adding gas without checking for leaks is just wasting your money.

How We Do It — Step by Step

Most technicians just refill the gas and leave. We do it differently.

✅ Step 1 — Full AC Inspection

Before touching the gas, we inspect your entire AC — indoor unit, outdoor unit, pipes and joints.

✅ Step 2 — Leak Test with Soap Foam

We apply soap foam on every pipe joint and connection point. If there is a leak, bubbles will appear — we find it and fix it first. No leak test, no gas refill — that's our rule.

✅ Step 3 — Pressure Check

We use a pressure gauge to check the current gas level and confirm how much needs to be refilled.

✅ Step 4 — Gas Refill

We refill with the correct gas type — R22, R32 or R410A — based on your AC model. The right gas in the right amount makes all the difference.

✅ Step 5 — Final Performance Check

After refilling, we run your AC and check the cooling performance — so we leave only when everything is working perfectly.


Why choose our AC Gas Refil service in Mohammadpur,Dhaka

Mohammadpur's housing society buildings present a specific gas leak challenge — the older copper pipe runs in these buildings have been in place for many years, and the flare connections made during the original installations were created with the tools and techniques of an earlier era. As these connections age, the copper flare faces oxidize and the sealing efficiency gradually degrades. A connection that sealed perfectly 8 years ago may now allow slow gas escape that the homeowner notices only as a gradual cooling decline. Our technicians performing gas refill calls in Mohammadpur are specifically experienced in assessing older-connection integrity — using both soap foam testing and, for suspect connections, nitrogen pressure hold testing that reveals leaks too slow for soap foam to detect reliably. Our Mohammadpur workshop, operating with refrigerant supply from Karim Refrigeration near Town Hall, stocks the R22 refrigerant that remains common in the older AC units throughout this area.

Our Other Services

◉ AC Basic Wash ◉ AC Foam Wash AC Jet Wash

◉ AC Master Servicing ◉ AC Installation

◉ AC Uninstall & Re-install ◉ AC Leak Repair

Pricing

Gas Type

1 Ton

1.5 Ton

2 Ton

R22

Starting from৳3,000

Starting from৳3,500

Starting from৳4,000

R32

Starting from৳2,500

Starting from৳3,000

Starting from৳3,500

R410

Starting from৳2,500  

Starting from৳3,000

Starting from৳3,500

R407

Starting from৳2,500

Starting from৳3,000

Starting from৳3,500

⚠️ If hanging or scaffolding is required, additional charge applies. Final price confirmed by technician on-site.


FAQ - Mohammadpur

▪️ How do I know if my AC needs gas refill?

If your AC runs but doesn't cool properly, takes too long to cool, or the outdoor unit runs non-stop — these are signs of low gas.

▪️ Why do you check for leaks before refilling?

If there is a leak and we just add gas, it will escape again within days or weeks. We fix the leak first so your gas lasts long — saving you money in the long run.

▪️ How long does gas stay after refilling?

If there is no leak, gas can last 2 to 5 years depending on usage and AC condition.

▪️ What gas type does my AC use?

It depends on your AC model. Our technician will check and use the correct type — R22 for older models, R32 or R410A for newer ones.

▪️ Is there a guarantee after gas refill?

Yes. 10-day guarantee. If gas drops again within 10 days due to a leak we missed, we come back and fix it for free.

Q: My Mohammadpur housing society AC has been losing gas gradually for years — is there a permanent fix?

A: Yes. The long-term solution is to identify every leaking connection and re-flare or replace it — not just top up the gas. We perform a comprehensive leak test on all circuit connections, repair every identified leak point and then refill. For older units with multiple degraded connections, we may recommend replacing the entire flare set during a single service visit, which is more cost-effective than addressing individual leaks repeatedly.

Q: Do you stock R22 gas for the older ACs common in Mohammadpur housing societies?

A: Yes. R22 refrigerant is stocked at our Karim Refrigeration supply point near Town Hall and available for same-day service throughout Mohammadpur. We are one of the few service providers in the area who still maintains consistent R22 availability for older units.

Q: How do you test for very slow leaks in Mohammadpur's older AC connections?

A: For leaks too slow for soap foam to detect reliably, we use nitrogen pressure hold testing — pressurizing the circuit with nitrogen and monitoring whether the pressure holds over a timed period. A pressure drop confirms a leak even when its location is not immediately visible.


How to order

Tap the call button on top of the page

Go to Contact page, select your service, enter your name, phone number and address — done!

📞 Call: 01736092803

💬 WhatsApp: 01736092803

Reviews of AC Gas Refill — Leak Test First, Then Refill

5.0
0 ratings
5
4
3
2
1

No reviews yet. Be the first to review!

Leave a Review

Details

Gas refill service active across Mohammadpur including Town Hall area, Krishi Market vicinity, PC Culture Housing, Tajmahal Road and all surrounding residential streets. Refrigerant supply including R22 supported by Karim Refrigeration near Town Hall. Nitrogen pressure hold testing available for slow-leak diagnosis in older Mohammadpur units.