AC Gas Refill — Leak Test First, Then Refill in Kafrul, Dhaka

5.0
0 Reviews
AC Gas Refill — Leak Test First, Then Refill

Overview of AC Gas Refill — Leak Test First, Then Refill in Kafrul

Your AC is running but the room is not getting cold? The most common reason is low refrigerant gas. But before we refill anything, we make sure the gas will actually stay — because adding gas without checking for leaks is just wasting your money.

How We Do It — Step by Step

Most technicians just refill the gas and leave. We do it differently.

✅ Step 1 — Full AC Inspection

Before touching the gas, we inspect your entire AC — indoor unit, outdoor unit, pipes and joints.

✅ Step 2 — Leak Test with Soap Foam

We apply soap foam on every pipe joint and connection point. If there is a leak, bubbles will appear — we find it and fix it first. No leak test, no gas refill — that's our rule.

✅ Step 3 — Pressure Check

We use a pressure gauge to check the current gas level and confirm how much needs to be refilled.

✅ Step 4 — Gas Refill

We refill with the correct gas type — R22, R32 or R410A — based on your AC model. The right gas in the right amount makes all the difference.

✅ Step 5 — Final Performance Check

After refilling, we run your AC and check the cooling performance — so we leave only when everything is working perfectly.


Why choose our AC Gas Refill in Kafrul,Dhaka

A family near Kafrul market had been told by a local technician that their AC needed gas refill — the technician had not used a pressure gauge but had concluded from the poor cooling alone that gas was low. They booked Service Wala for a second opinion before spending money on gas. When our technician arrived at their Kafrul building and measured the system pressure with a calibrated gauge, the reading was within the correct specification for the ambient temperature that day. No gas shortage existed. The poor cooling was caused by a contaminated condenser — the outdoor unit fins were loaded with road dust from the Kafrul market area. After outdoor condenser cleaning, the system pressure remained the same and the cooling performance was fully restored. No gas was added. The family gave us a five-star review and mentioned the second opinion had saved them the cost of unnecessary gas that would have had no effect. We provide accurate AC gas refill service — with pressure measurement before any gas addition — throughout all Kafrul areas. 

Our Other Services

◉ AC Basic Wash ◉ AC Foam Wash ◉ AC Jet Wash

◉ AC Master Servicing ◉ AC Installation

◉ AC Uninstall & Re-install ◉ AC Leak Repair

Pricing

Gas Type

1 Ton

1.5 Ton

2 Ton

R22

Starting from৳3,000

Starting from৳3,500

Starting from৳4,000

R32

Starting from৳2,500

Starting from৳3,000

Starting from৳3,500

R410

Starting from৳2,500  

Starting from৳3,000

Starting from৳3,500

R407

Starting from৳2,500

Starting from৳3,000

Starting from৳3,500

⚠️ If hanging or scaffolding is required, additional charge applies. Final price confirmed by technician on-site.


FAQ - Kafrul

▪️ How do I know if my AC needs gas refill?

If your AC runs but doesn't cool properly, takes too long to cool, or the outdoor unit runs non-stop — these are signs of low gas.

▪️ Why do you check for leaks before refilling?

If there is a leak and we just add gas, it will escape again within days or weeks. We fix the leak first so your gas lasts long — saving you money in the long run.

▪️ How long does gas stay after refilling?

If there is no leak, gas can last 2 to 5 years depending on usage and AC condition.

▪️ What gas type does my AC use?

It depends on your AC model. Our technician will check and use the correct type — R22 for older models, R32 or R410A for newer ones.

▪️ Is there a guarantee after gas refill?

Yes. 10-day guarantee. If gas drops again within 10 days due to a leak we missed, we come back and fix it for free.

Q: A local technician told me my Kafrul AC needs gas refill without using a gauge — should I trust this?
A: No. Refrigerant level cannot be determined without pressure measurement using a calibrated gauge. A technician who concludes gas is needed from cooling performance alone — without measuring — is guessing. We measure before recommending and add gas only when measurement confirms it is needed.

Q: If my Kafrul AC does need gas, do you find the leak first?
A: Yes. Gas does not deplete without a leak. Adding gas without finding and repairing the leak means the new gas will also escape — requiring another refill within months. We locate the leak, repair it and then recharge to the correct pressure.

How to order

Tap the call button on top of the page

Go to Contact page, select your service, enter your name, phone number and address — done!

📞 Call: 01736092803

💬 WhatsApp: 01736092803

Reviews of AC Gas Refill — Leak Test First, Then Refill

5.0
0 ratings
5
4
3
2
1

No reviews yet. Be the first to review!

Leave a Review

Details

AC gas refill service active throughout Kafrul main area and all surrounding residential streets. Pressure measurement before gas recommendation. Leak detection and repair before recharge. Same-day service available.